four stars
"General Purpose"amplifier
Positive features:
60 Vpp maximal output voltage
Bandwidth 7 MHz at a gain of 1000 (see measurement 2)
Total Harmonic Distortion 0,01% (10 kHz, gain 60 dB, load 390 Ohm, 28 Vpp, see measurement 4)
dual supply +/-10V to +/-35V
Negative features:
high fuel consumption
Design: as AC coupled amplifier usable approx. starting from 20 cycles per second, firmly stopped not inverting gain of 1000. Large operating voltage range, short circuit proof.
Applications:
preamplifier for spectrum analyzers or scopes
low distortion high gain
adjustable simple noise generator
ultra fast gain monster within closed amplifier loops
music signals - yes would be possible
Amplifier in completely soldered copper housings. The housing is a good heat dissipation. At the side soldered entrance to the offset trimmer. The closed copper housing is a very good shielding against disturbances. |
![]() On the top side soldered on brass cooling fins. The inlets are laid out as shielding capacitor with a metallic hose. Up to now I did not repent that to solder yet. (tin opener - no thank you) |
![]() Measurement 1 - measurement assembly at 1 MHz and 18mV on input. Equipment HP3336B sine level generator, Tektronix 7904 scope, simple regulated power supply. |
![]() |
frequency response characteristic: 7 MHz bandwidth -3 dB at 60 dB 0.5 dB gain variation over 4.5 decades positive low frequency phaseshift by correction and AC-coupling (input amplitude 14 mV, supply +/-20V) |
|
What did I forget? to adjust the gain to exactly 60.0 dB - now them are 59.7 dB - if it is disturbing for you, then send me nevertheless please a tin opener and a box italian Ravioli, then I perhaps correct it. The phase shift for low frequencies is too large, the AC coupling works too late - design remains in such a way and won't change. A note for phase shift and at the same time a memory of the school medicine: with very high frequencies the phase turns beyond the magic 180°, and the reinforcement is still larger than 1 - where the oscillation remains? The phase shift at the "genuine point of inverse feedback" of the automatic control loop is crucial. This sits deeply the inside one the amplifier. The phase shift at the point of inverse feedback is again corrected by the frequency response of the inverse feedback networks - however the fun begins exactly there to build an amplifier and ends there the fun often also again. The amplifier shown anyhow could be further improved in its frequency response by very intensive corrective measures. This amplifier however certainly not more - however the next guarantees. |
||
Measurement 1- scopescreen with 1 MHz and 18mV. An visible wave distortion can't be noted. Tektronix scope 7904 using 7A26 amplifier and 7B85 timebase. |
Measurement 2 - 1 kHz and 59.8 dB. Recording the bode diagram with a HP3575A, capable to measure a maximum of 13 MHz. Direct flashing was a wrong photographing. |
Measurement 2 - the -3 dB bandwidth, frequency of 7 MHz, gain 56.7 dB. This time without flash. Adjusting balance of room and scope illumination it's a hard task. |
Measurement 2 - scopescreen with a bandwidth of 7 MHz. Amplitude input voltage 14 mV. Power supply voltage +/-20 volt. Output signal clearly disturbed. |
Measurement 2 -flashing under this angle was not a good idea. Through the short eposure time not all numbers can be showed faultless. The video cable is terminated with the generators impedance of 75 ohms. |
Measurement 3 - applied a clean 10 kHz sine to the amplfiers input, outputs +11dBVrms (5 Vp). 2nd harmonic at 20 kHz and -84 dBc. Distortion 0.006%. 1000 seconds sweep time. |
Measurement 3 - easy to see close to the carrier there are mixing products probably caused by line AC of the external amplifier power supply. |
Measurement 4 - output amplitude 20 dBVrms (28 Vpp) 10 kHz under a load of 390 ohms. The amplifier isn't impressed very much. K2 keeps in comparison with measurement 2 almost unchanged. K3 increases to -80 dBc about 0.01%. |
Measurement 3 and 4 - An HP350D using as attenuator for the ultra low distortion 10 kHz signal. The attenuator has an impedance of 600 Ohm and is an excellent choice for this purpose. This time I was lucky with the direct flashing. |
Measurement 5 - shows output noise of the amplifier with an open input, only terminated by a internal 2.2 Meg resistor. The thermal resistor noise and the added bias input currents are amplified by the wideband 60 dB gain. |
Measurement 5 - output noise with a time base of 2ms/div. Visible single peaks up to 2 volt. The RMS value of this noise can be wonderful adjusted by the choice of the source impedance. For this photo the Illumination has been reduced. |
Measurement 6 - spectrum analyzer Tektronix 7L12 with an open input. Top refence line level 0 dBm. The peak in the middle is the DC center frequency. One division 2 MHz and 10 dB vertical. Dynamic analyzer range about 65 dB. |
Measurement 7 - analyzer settings as in measurement 6. The amplifier is connected to the analyzers input. Amplifier input terminated with a 50 ohms resistor. Less additional noise caused by the amp. |
Measurement 8 - amplifier grounded with internal 2.2 Meg only, resulting a noise fireworks. Please note the photo's straight lines in the border areas. Minolta's MD50 macro objective works fine. |
Measurement 8 - input 2.2 Meg. New analyzer settings, the center frequency moved on the left side. Span reduced to 1 MHz/DIV. At higher frequency limits the bandwidth of the amplifier additional noise. |
"A good amplifier is a never ending task".